Turbine Flowmeter – BSP Screwed, Model NT

Specification

  • Flow Ranges: 1 to 2250 litres/min Water (or equivalent)
  • Accuracy: Better than ±0.5% of reading
  • Repeatability: ± 0.1% of reading
  • Pressure: Maximum 35 barg (options upto 350 barg)
  • Temperature: -30ºC to 110ºC standard
    (high temp option -30 to 232ºC)
  • Process Connections: BSP parallel, 10 sizes ⅜˝ to 2½˝
  • Output Signal: Frequency pick-off, individually calibrated with unique K factor
  • Materials of Construction: Body: 316 stainless steel
    Bearings: PTFE standard, optional tangsten carbide
    Thrust balls: tungsten carbide
    Rotar: 431 stainless steel or ferralium
    Rotar shaft: tungsten carbide
    Hangers: 316 stainless steel
    Circlips: 316 stainless steel

Options

  • Process Connections: Specials available for other hydraulic connections
  • Pick – off: Intrinsically safe option available
  • Calibration: Other liquid calibrations – certification available
  • Displays: See displays section for digital, rate, totalisers and batch control options