DS 210 Low Range, Three in One

Specification

  • Range: 10mbar through to 1000mbar
  • Output: Volts or 4-20mA, 1 or 2 x PNP switches
  • Sensor Technology: Silicon / Stainless Steel, Piezoresistive
  • Accuracy: <±0.175%
  • Overpressure: Minimum 2.5 × rated calibrated range
  • Maximum Process Temperature: 90ºC
  • Electrical Connection: Options DIN 43650, M12, BINDER, Cable Gland
  • Materials of Construction: Stainless Steel, RTV, Ceramics, FKM Seals
  • Process Connections: G¼” and G½” to EN 837, G¼” to DIN 3852
  • For Display specification see: PA 430

Options

  • Ex-Options available
  • For Remote Displays, see Electronic and Digital Displays section